Home >> Product >> Telephone Cable >> Ordering Information |
| |
|
VDE Order Code |
|
| |
| A-BCDEFG HxI…JKLMN |
| For Example: |
| Outdoor Telephone Cables |
| A-2YF(L)2Y…25X2X0.4 StIII Bd |
| |
Outdoor telephone cable, solid PE insulated, jelly filled, PE coated aluminium tape bonded with PE sheath, star quad & unit stranding, 25 Pairs 0.4mm to VDE 0816/DIN57816 |
| A-2Y(L)2Y…25X2X0.4 StIII Bd |
| |
Outdoor telephone cable, solid PE insulated, PE coated aluminium tape bonded with PE sheath, star quad & unit stranding, 25 Pairs 0.4mm to VDE 0816 |
| A-02YF(L)2Y…25X2X0.6 StIII Bd |
| |
Outdoor telephone cable, Cellular PE insulated, jelly filled,PE coated aluminium tape bonded with PE sheath, star quad & unit stranding, 25 Pairs 0.6mm to VDE 0816 |
| A-02YSF(L)2YB2Y…25x2x0.6 StIII Bd |
| |
Outdoor telephone cable, foam skin insulated, jelly filled,PE coated aluminium tape bonded with PE sheath, double galvanized steel tape armoured, star quad & unit stranding,PE oversheathed, 25 Pairs 0.6mm to VDE 0816 |
| Indoor Telephone Cables |
| J-Y(St)Y…10X2X0.6 Lg |
| |
Installation cable, PVC Insulated, static shield of plastic backed aluminium Tape, PVC Sheathed, stranded in layers,10 pairs 0.6mm to VDE 0815 |
| J-2Y(St)Y…10X2X0.4 StIII Bd |
| |
Installation cable, solid PE Insulated, static shield of plastic backed aluminium Tape, PVC Sheathed, star quad and unit stranding 10 pairs 0.4mm to VDE 0815/0816 |
| J-YY… 10X2X0.6 Bd |
| |
Installation cable, PVC Insulated, PVC Sheathed, star quad and unit stranding 10 pairs 0.6mm to VDE 0815/DIN 57815 Outdoor Telephone Cables with protection against inductive influences. |
| AJ-2Y(St)YbY…10X4X1.4 S Lg (fK) (2B 0.5) |
| |
Outdoor Telephone Cable for railway signaling - Solid PE Insulated, aluminium tape shielded, PVC sheathed,stranded in layers, copper tape with two layers of steel tape of 0.5mm, 10 Quads 1.4mm |
| AJ-2YDYbY…7X4X1.4 S Lg (25…Cu/2B 0.5) |
| |
Outdoor Telephone Cable for railway signaling - Solid PE Insulated, copper wire shielded, PVC sheathed, stranded in layers, 1.2mm copper wire shield cross section 25mmsq,with two layers of steel tape of 0.5mm, 7 Quads 1.4mm |
| |
|
|
| A Basic Types |
| |
| A- |
Outdoor telephone cables |
| S- |
Switchboard cables |
| J- |
Installation cables |
| JE- |
Fire Alarm cables |
| AJ- |
Outdoor cable with protection against inductive influences |
| T- |
Terminating cable |
|
| B Insulation Types |
| |
| 02Y |
Cellular PE |
| 2Y |
Solid PE |
| 02YS |
Foam Skin Insulating cover of cellular PE with additional skin of solid polyolefine. |
| Y |
PVC |
| H |
LSZH |
|
| C Filling |
| |
| F |
Petroleum jelly filling |
| Blank |
Unfilled |
|
| D Screening Material |
| |
| (St) |
Static shield of plastic-backed aluminum Tape for indoor cables |
| D |
Shield of copper wire whipping over one stranding element (e.g. pair) |
| LR |
Corrugated alumnium tape |
| Blank |
No screen |
|
| E Bedding Material |
| |
| 2Y |
PE |
| Y |
PVC |
| H |
LSZH |
| M |
Lead Sheath |
| MZ |
Special Alloyed Lead Sheath |
| Blank |
No Bedding |
|
| F Armouring Material |
| |
| b |
Armouring |
| SR |
Corrugated steel tape |
| T |
Messenger of galvanized steel wires. |
| Blank |
No Armour |
|
| G Sheath Material |
| |
| 2Y |
PE |
| Y |
PVC |
| H |
LSZH |
| (L)2Y |
Laminated sheath (shield of PE coated aluminium tape bonded with PE sheath). |
| M |
Lead Sheath |
| MZ |
Special Alloyed Lead Sheath |
| Blank |
No Sheath |
|
| H Number of Pairs/Quads |
| |
|
| I Conductor Size |
| |
| 0.4 |
0.4mm |
| 0.5 |
0.5mm |
| 0.6 |
0.6mm |
| 0.8 |
0.8mm |
| 0.9 |
0.9mm |
|
| J Stranding Element |
| |
| PiC |
Pairs shielded with copper braid |
| PiMF |
Pairs shielded with aluminium/polyester tape |
| St |
Star Quad(Phantom) |
| StI |
Star Quad(trunk cable) |
| StIII |
Star Quad (local cable) |
| TIC |
Triple shielded with copper braid |
| TiMF |
Triple shielded with aluminium/polyester tape |
|
| K Cable Type |
| |
| S |
Railway signaling cable |
|
| L Types of Stranding |
| |
| Lg |
Stranded in layers |
| Bd |
Unit Type stranding |
|
| M Copper/Steel Tape/Braid Screen Options |
| |
| (…Cu) |
Total cross section of copper shield in mm sq |
| (fK) |
Longitdinally applied copper tape, supplement to (St) |
| 2B… |
two layers of steel tape, thickness of steel tape in mm |
|
| N Fire Resistance Options |
| |
| E30 |
30mins circuit integrity according to DIN VDE 4102 Part 12 |
| E60 |
60mins circuit integrity according to DIN VDE 4102 Part 12 |
| F180 |